深蓝快车 www.chinama.com.cn 中文网站 www.chinama.com.cn 英文网站
(ibm、hp、sun、oracle)小型机、服务器、存储专业技术服务

ibm power10 9105-41B, 9105-42A, or 9786-42H system parts 销售和技术服务

产品

技术

配件

IT疑难问题解决方案1

IT疑难问题解决方案2

小型机服务

服务器服务

存储服务

维保

机房搬迁

操作系统|双机

数据库

备份/恢复

Oracle灾备

应急服务

楼宇监控

深蓝快车

技术中心

案例

联系我们

ibm POWER10 Part Number 01
IBM Power10 9028-21B system parts 销售和技术服务
IBM Power10 9028-21B system parts 销售和技术服务 01
IBM Power10 9105-22A, 9105-22B, or 9786-22H system parts 销售和技术服务
IBM Power10 9105-22A, 9105-22B, or 9786-22H system parts 销售和技术服务 01
IBM Power10 9105-41B, 9105-42A, or 9786-42H system parts 销售和技术服务
IBM Power10 9105-41B, 9105-42A, or 9786-42H system parts 销售和技术服务 01
IBM Power10 9043-MRX system parts 销售和技术服务
IBM Power10 9043-MRX system parts 销售和技术服务 01
IBM Power10 9080-HEX system parts 销售和技术服务
IBM Power10 9080-HEX system parts 销售和技术服务 01
IBM Power10系列小型机、疑难问题解决方案电话: 13301272832 (微信同号)
Sitemap
Sitemaps
Sitemapsall
Moble: 13301272832 (微信同号)
Tel:  13301272832
联系人:   霍 工
QQ:   619804118
E-mail:   bjslkc@163.com
公司:北京深蓝融鑫科技发展有限公司
ibm power10 9105-41B, 9105-42A, or 9786-42H system parts 销售和技术服务
Table 1. System parts
9105-41B, 9105-42A, or 9786-42H system parts
Last Updated
: 2025-06-16
Indexed drawings show system part numbers of each part.
Rack final assembly
Cover assembly
Table 1. Rack assembly part numbers
Index number
CCIN
Part number
Units per assembly
Description
1 02YK262 1 Front bezel (systems with an RDX drive)
02YK264 1 Front bezel (systems without an RDX drive)
2 1 Electronic Industries Association (EIA) latch (left)
3 3 Screws
4 02YK554 Slide rail kit - contains left and right slide rails and attaching screws
5 02YK578 Air baffle
6 1 Top cover assembly
7 02FJ807 Cable management arm assembly
8 02YK554 Slide rail kit - contains left and right slide rails and attaching screws
9 1 EIA latch (right)
10 3 Screws
System parts
System parts
Table 2. System part numbers
Index number
CCIN
Part number
Units per assembly
Description
11 5949 02YC661 0-16 800 GB 7 mm NVMe U.2 drive
Note: Supported only on the AIX® and Linux® operating systems.
59B7 02YC615 0-16 800 GB 7 mm NVMe U.2 drive
Note: Supported only on the AIX and Linux operating systems.
5947 01LU974 0-16 800 GB 15 mm NVMe U.2 drive
Note: Supported only on the IBM® i operating system.
5950 02YC895 or 02YC911* 0-16 800 GB 15 mm NVMe U.2 drive
5B53 02YC724 or 02YC738* 0-16 800 GB 15 mm NVMe U.2 drive
11 5951 02YC896 or 02YC912* 0-16 1600 GB 15 mm NVMe U.2 drive
59B8 01LU967 0-16 1600 GB 15 mm NVMe U.2 drive
5B52 02YC725 or 02YC739* 0-16 1600 GB 15 mm NVMe U.2 drive
5952 02YC897 or 02YC913* 0-16 3200 GB 15 mm NVMe U.2 drive
59B9 01LU968 0-16 3200 GB 15 mm NVMe U.2 drive
5B51 02YC726 or 02YC740* 0-16 3200 GB 15 mm NVMe U.2 drive
5953 02YC898 or 02YC914* 0-16 6400 GB 15 mm NVMe U.2 drive
59BA 01LU969 0-16 6400 GB 15 mm NVMe U.2 drive
5B50 02YC727 or 02YC741* 0-16 6400 GB 15 mm NVMe U.2 drive
5941 02YC749 or 02YC940* 0-16 15360 GB 15 mm NVMe U.2 drive
12 6B89 02WG681 2 Drive backplane
13 02YK424 1 Drive backplane signal cable for the drive backplane at location P1
02YK423 1 Drive backplane signal cable for the drive backplane at location P2
14 02YK420 2 Drive backplane power cable
15 6B85 02PX028 1 Control panel (rack-mounted systems)
Note: For the control panel for stand-alone systems, see Table 6.
16 02YK427 1 Control panel cable (rack-mounted systems)
Note: For the control panel cable for stand-alone systems, see Table 6.
17 02YK429 1 Fan signal cable
18 02YK416 2 Fan cable for the fan at location A4 or fan cable for the fan at location A5
19 02YK431 1 Front USB cable (9105-41B)
Note: One end of the USB cable is connected to the USB front connector and the other end of the USB cable is connected to an RDX drive (when available).
20 02YK427 1 Control panel display cable (rack-mounted systems)
Note: For the control panel display cable and holder for stand-alone systems, see Table 6.
21 6B86 02WF367 1 Control panel display
22 02YK159 1 Drive backplane filler
23 Screws
24 01ML137 0-16 Drive filler
25 7B5F 02YK323 4-6 Fan
26 0-2 Fan filler
* Order the same part number as the drive that you are replacing.
Additional system parts
Additional system parts
Table 3. Additional system part numbers
Index number
CCIN
Part number
Units per assembly
Description
27 329A 78P7343 2-32 16 GB DDR4 DDIMM (low-profile)
27 327A 78P7344 2-32 32 GB DDR4 DDIMM (low-profile)
27 327B 78P7345 2-32 64 GB DDR4 DDIMM (low-profile)
27 327C 78P7346 2-32 128 GB DDR4 DDIMM (low-profile)
27 32AD 01GY917 2-32 128 GB DDR4 DDIMM (full-height)
27 32AE 01GY925 2-32 256 GB DDR4 DDIMM (full-height)
27 32A1 03HD880 2-32 32 GB DDR5 DDIMM (low-profile)
27 32A2 03HD881 2-32 64 GB DDR5 DDIMM (low-profile)
27 3298 03HD800 2-32 128 GB DDR5 DDIMM (full-height)
27 3299 03HD801 2-32 256 GB DDR5 DDIMM (full-height)
27 02YK346 0-30 DIMM filler (low-profile)
27 03KY090 0-30 DIMM filler (full-height)
28 02YK112 Memory retainer for low-profile memory in locations P0-C27 through P0-C37 or P0-C38 through P0-C48
02YK349 Memory retainer for full-height memory in locations P0-C27 through P0-C37 or P0-C38 through P0-C48
29 02YK115 Memory retainer for memory locations P0-C12, P0-C13, P0-C25, or P0-C26
30 02YK114 Memory retainer for low-profile memory in locations P0-C16 through P0-C21
02YK127 Memory retainer for full-height memory in locations P0-C16 through P0-C21
31 2E32 02CM285 1-2 Voltage regulator module
32 6B59 02WF429 1 Trusted platform module
33 6B58 1 eBMC card
Notes:
For systems with system firmware level FW1020.xx, order part number 02WF419.
For systems with system firmware level FW1030.xx or later, order part number 03KP669.
34 02YK226 0-1 Voltage regulator module filler
35 00FW701 1 Power signal cable
Additional system parts (continued)
Additional system parts (continued)
Table 4. Additional system parts (continued)
Index number
CCIN
Part number
Units per assembly
Description
36 00E8903 0-11 Adapter filler
37 01GY346 11 Adapter divider
38 Cryptographic Coprocessor. Use the feature code of the adapter to find the FRU number in Adapter information by feature code.
39 Adapter. Use the feature code of the adapter to find the FRU number in Adapter information by feature code.
40 Cable adapter. Use the feature code of the adapter to find the FRU number in Adapter information by feature code.
41 0-2 NVMe JBOF adapter. Use the feature code of the adapter to find the FRU number in Adapter information by feature code.
42 02YK417 0-1 NVMe cable for the drive backplane at location P1.
43 02YK418 0-1 NVMe cable for the drive backplane at location P2.
44 02YK399 NVMe JBOF cable bracket
45 2B1D 03FP725 4 1200 W power supply (9105-41B stand-alone systems)
2B1E 03FP728 2 1600 W power supply (9105-41B rack-mounted systems)
4 1600 W power supply (9105-42A or 9786-42H)
46 94Y9445 0-4 Power supply filler
Additional system parts (concluded)
Additional system parts (concluded)
Table 5. Additional system parts (concluded)
Index number
CCIN
Part number
Units per assembly
Description
47 00RY543 1 Time-of-day battery
48 5C88 02YK846 1 System processor module kit (includes 4 core DD2.x processor module, processor handling tool, 4 mm Hex driver, TIM, tweezers, and air pump) (9105-41B)
5C8A 02YK847 1 System processor module kit (includes 8 core DD2.x processor module, processor handling tool, 4 mm Hex driver, TIM, tweezers, and air pump) (9105-41B)
5CF9 02YK881 1 System processor module kit (includes 24 core DD2.x processor module, processor handling tool, 4 mm Hex driver, TIM, tweezers, and air pump) (9105-41B rack-mounted systems)
48 5C84 02YK843 2 System processor module kit (includes 12 core DD2.x processor module, processor handling tool, 4 mm Hex driver, TIM, tweezers, and air pump) (9105-42A or 9786-42H)
5C83 02YK841 2 System processor module kit (includes 16 core DD2.x processor module, processor handling tool, 4 mm Hex driver, TIM, tweezers, and air pump) (9105-42A or 9786-42H)
5C82 02YK839 2 System processor module kit (includes 30 core DD2.x processor module, processor handling tool, 4 mm Hex driver, TIM, tweezers, and air pump) (9105-42A or 9786-42H)
49 02YK828 2 Heat sink kit (includes heat sink, TIM, and tweezers)
50 2E2F 03KP324 1 System backplane (9105-42A or 9786-42H)
2E40 03KP323 1 System backplane (9105-41B)
51 Screws
52 1 Chassis
Miscellaneous system parts
Table 6. Miscellaneous system parts
Description
CCIN
Part number
Units per assembly
Control panel display filler 01ML157 1
Control panel display cable filler (stand-alone systems) 01ML159 1
Control panel (stand-alone systems) 6B85 02WF537 1
Control panel cable (stand-alone systems) 01ML059 1
Control panel display cable and holder (stand-alone systems) 01ML096 1
Memory module divider bracket (low-profile) 02YK755 5 - 25
Memory module divider bracket (full-height) 02YK756 5 - 25
RDX docking station filler 0-1
RDX docking station power cable 01GY348 0-1
RDX docking station 46C2443 0-1
RDX docking station latch 01GY411 0-1
Socket dust cover 03FP753 0-1
Tower cover (stand-alone systems with an RDX drive) 02YK196 1
Tower cover (stand-alone systems without an RDX drive) 02YK192 1
Tower door (stand-alone systems) 02YK193 1
Tower cover, left (stand-alone systems) 02YK284 1
中国·北京 联系方式:
1)联系人:   霍经理
2)手 机: 13301272832 (微信同号)
3)E-mail:   bjslkc@163.com
4)公司:北京深蓝融鑫科技发展有限公司
5)地址:北京市海淀区西北旺
6)公司地址、乘车路线及公司位置地图
 

Beijing DeepBlue the Rongxin Technology Development Co., Ltd. All Rights Reserved.
北京深蓝融鑫科技发展有限公司版权所有,不得转载.
京ICP备05042544号