HP 9000 700 workstations
PA-RISC workstations were sold in many different formats, from rather small 712, 715 and B-Class desktop to
the heavy and powerful
735/755 and C-Class workstations.
↑ up.
Visualize workstations
PA-RISC workstations with lettered model names sold under the Visualize brand during the 1990s.
↑ up.
Portable PA-RISC workstations
Three portable PA-RISC workstations were produced for mobile measurement and control by third-party
vendors.
The RDI and SAIC designs are based on HP 9000/712 and C132L workstations designs.
↑ up.
HP 9000 800 servers
The HP 9000/800 were the original 32-bit PA-RISC servers with distinct architecture and heavy cases.
The HP 9000/500 series were the original HP 9000 computers and the predecessor to PA-RISC.
| Model |
CPU |
Cache |
RAM |
Design |
Expansion |
Operating systems |
|
| 520 (9020) |
1-3 FOCUS 18 MHz |
16 KB |
10 MB |
IOP/MPB |
HP-IB, GP-IO, CIO |
HP-UX, HP BASIC |
| 530 (9030) |
1-3 FOCUS 18 MHz |
16 KB |
10 MB |
IOP/MPB |
HP-IB, GP-IO, CIO |
HP-UX, HP BASIC |
| 540 (9040) |
1-3 FOCUS 18 MHz |
16 KB |
10 MB |
IOP/MPB |
HP-IB, GP-IO, CIO |
HP-UX, HP BASIC |
| 550 (9050) |
1-3 FOCUS 18 MHz |
16 KB |
10 MB |
IOP/MPB |
HP-IB, GP-IO, CIO |
HP-UX, HP BASIC |
| 635SV |
NS-1 30 MHz |
128 KB |
96/112 MB |
SIU
| CIO |
HP-UX, HPBSD Mach
3/UX
Chorus |
| 645SV |
NS-2 27.5 MHz |
256 KB |
96/112 MB |
SIU
| CIO |
HP-UX |
| 808 |
PCX |
32 KB |
32 MB |
SPI
| HP-PB |
HP-UX |
| 815 |
PCX |
32 KB |
56 MB |
SPI
| HP-PB |
HP-UX |
| 822 |
NS-2 25 MHz |
32 KB |
128 MB |
SIU
| HP-PB |
HP-UX |
| 825 |
NS-1 25 MHz |
16 KB |
96/112 MB |
SIU
| CIO |
HP-UX |
| 832 |
NS-2 30 MHz |
128 KB |
128 MB |
SIU
| HP-PB |
HP-UX |
834 835 |
NS-1 30 MHz |
128 KB |
96/112 MB |
SIU
| CIO |
HP-UX, HPBSD Mach
3/UX
Chorus |
| 840 |
TS-1 8 MHz |
128 KB |
96/112 MB |
CTB
| CIO |
HP-UX |
| 842 |
PCX 32 MHz |
1 MB |
? MB |
SPI
| HP-PB |
HP-UX |
| 845 |
NS-2 27.5 MHz |
256 KB |
96/112 MB |
SIU
| CIO |
HP-UX |
| 850 |
NS-1 27.5 MHz |
128 KB |
256 MB |
SIU
| CIO |
HP-UX |
| 852 |
PCX 50 MHz |
1 MB |
? MB |
SPI
| HP-PB |
HP-UX |
| 855 |
NS-2 27.5 MHz |
256 KB |
256 MB |
SIU
| CIO |
HP-UX |
| 860 |
NS-2 27.5 MHz |
1 MB |
256 MB |
SIU
| CIO |
HP-UX |
| 865 |
PCX 50 MHz |
768 KB |
512 MB |
SPI
| CIO |
HP-UX |
| E25 |
PA-7100LC 48 MHz |
64 KB |
512 MB |
LASI |
HP-PB |
HP-UX Linux
NetBSD |
| E35 |
PA-7100LC 64 MHz |
256 KB |
512 MB |
LASI |
HP-PB |
HP-UX Linux
NetBSD |
| E45 |
PA-7100LC 80 MHz |
256 KB |
512 MB |
LASI |
HP-PB |
HP-UX Linux
NetBSD |
| E55 |
PA-7100LC 96 MHz |
1 MB |
512 MB |
LASI |
HP-PB |
HP-UX Linux
NetBSD |
| F10 |
PA-7000 32 MHz |
96 KB |
768 MB |
Viper |
HP-PB |
HP-UX |
| F20 |
PA-7000 48 MHz |
128 KB |
768 MB |
Viper |
HP-PB |
HP-UX |
| F30 |
PA-7000 48 MHz |
512 KB |
768 MB |
Viper |
HP-PB |
HP-UX |
| G30 |
PA-7000 48 MHz |
512 KB |
768 MB |
Viper |
HP-PB |
HP-UX |
| G40 |
PA-7100 64 MHz |
512 KB |
768 MB |
Viper |
HP-PB |
HP-UX |
| G50 |
PA-7100 96 MHz |
512 KB |
768 MB |
Viper |
HP-PB |
HP-UX |
| G60 |
PA-7100 96 MHz |
2 MB |
768 MB |
Viper |
HP-PB |
HP-UX |
| G70 |
1-2 PA-7100 96 MHz |
4 MB |
768 MB |
Viper |
HP-PB |
HP-UX |
| H20 |
PA-7000 48 MHz |
128 KB |
768 MB |
Viper |
HP-PB |
HP-UX |
| H30 |
PA-7000 48 MHz |
512 KB |
768 MB |
Viper |
HP-PB |
HP-UX |
| H40 |
PA-7100 64 MHz |
512 KB |
768 MB |
Viper |
HP-PB |
HP-UX |
| H50 |
PA-7100 96 MHz |
512 KB |
768 MB |
Viper |
HP-PB |
HP-UX |
| H60 |
PA-7100 96 MHz |
2 MB |
768 MB |
Viper |
HP-PB |
HP-UX |
| H70 |
1-2 PA-7100 96 MHz |
4 MB |
768 MB |
Viper |
HP-PB |
HP-UX |
| I30 |
PA-7000 48 MHz |
512 KB |
768 MB |
Viper |
HP-PB |
HP-UX |
| I40 |
PA-7100 64 MHz |
512 KB |
768 MB |
Viper |
HP-PB |
HP-UX |
| I50 |
PA-7100 96 MHz |
512 KB |
768 MB |
Viper |
HP-PB |
HP-UX |
| I60 |
PA-7100 96 MHz |
2 MB |
768 MB |
Viper |
HP-PB |
HP-UX |
| I70 |
1-2 PA-7100 96 MHz |
4 MB |
768 MB |
Viper |
HP-PB |
HP-UX |
↑ up.
Lettered servers (HP 9000 800)
The lettered servers included 32 and 64-bit designs from the 700 and 800 series, from smaller towers
in D-Class/E-Class to
to deskside or cabinet systems in the K-Class.
↑ up.
Integrity (rp) servers
PA-RISC servers were called rp series around the turn of the century, almost all 64-bit rack
systems.
↑ up.
Itanium
HP produced three Itanium workstations before dropping Unix workstations completely,
making these the last and probably fastest HP-UX workstations (that also run Windows!).
| Model |
CPU |
Cache |
RAM |
Design |
Expansion |
Operating systems |
|
| i2000 |
1-2 Itanium
733-800 MHz |
varies |
16 GB |
82460GX |
PCI AGP |
HP-UX, Linux, FreeBSD, Windows |
| zx2000 |
Itanium 2 900 MHz-1.5 GHz |
varies |
8 GB |
zx1 |
PCI-X AGP |
HP-UX, Linux, FreeBSD, Windows, OpenVMS |
| zx6000 |
Itanium 2 900 MHz-1.5 GHz |
varies |
24 GB |
zx1 |
PCI-X AGP |
HP-UX, Linux, FreeBSD, Windows, OpenVMS |
HP also released a line of Itanium-based servers in the rack-mountable Integrity rx line.
| Model |
CPU |
Cache |
RAM |
Design |
Expansion |
Operating systems |
|
rx1600 rx1600-2 |
1-2 Itanium 2 1.0 GHz |
varies |
16 GB |
zx1 |
PCI-X |
HP-UX, Linux, Windows, OpenVMS |
| rx1620 |
1-2 Itanium 2 1.3-1.6 GHz |
varies |
16 GB |
zx1 |
PCI-X |
HP-UX, Linux, Windows, OpenVMS |
rx2600 rx2600-2 |
1-2 Itanium 2 1.0-1.5 GHz |
varies |
24 GB |
zx1 |
PCI-X |
HP-UX, Linux, Windows, OpenVMS |
| rx2620 |
1-2 Itanium 2 1.3-1.6 GHz |
varies |
32 GB |
zx1 |
PCI-X |
HP-UX, Linux, Windows, OpenVMS |
| rx2660 |
1-2 Itanium 2 1.4-1.6 GHz |
varies |
32 GB |
zx2 |
PCI-X |
HP-UX, Linux, Windows, OpenVMS |
| rx3600 |
1-2 Itanium 2 1.4-1.6 GHz |
varies |
192 GB |
zx2 |
PCI-X |
HP-UX, Linux, Windows, OpenVMS |
| rx4610 |
2-4 Itanium 733-800 MHz |
varies |
64 GB |
zx1 |
PCI |
HP-UX, Linux, Windows |
rx4640 rx4640-8 |
1-4 Itanium 2 1.1-1.6 GHz |
varies |
64 GB |
zx1 |
PCI-X |
HP-UX, Linux, Windows, OpenVMS |
rx5670 rx5670-4 |
1-4 Itanium 2 1.3-1.5 GHz |
varies |
96 GB |
zx1 |
PCI-X |
HP-UX, Linux, Windows, OpenVMS |
| rx6600 |
1-4 Itanium 2 1.4-1.6 GHz |
varies |
192 GB |
zx2 |
PCI-X |
HP-UX, Linux, Windows, OpenVMS |
rx7620 rx7620-16 |
2-8 Itanium 2 1.1-1.5 GHz |
varies |
64 GB |
SX1000 |
PCI-X |
HP-UX, Linux, Windows, OpenVMS |
rx7640 rx7640-16 |
2-8 Itanium 2 1.4-1.6 GHz |
varies |
256 GB |
SX2000 |
PCI-X |
HP-UX, Linux, Windows, OpenVMS |
rx8620 rx8620-32 |
2-16 Itanium 2 1.1-1.6 GHz |
varies |
256 GB |
SX1000 |
PCI-X |
HP-UX, Linux, Windows, OpenVMS |
rx8640 rx8640-32 |
2-16 Itanium 2 1.4-1.6 GHz |
varies |
512 GB |
SX2000 |
PCI-X |
HP-UX, Linux, Windows, OpenVMS |
| rx9610 |
4-16 Itanium 733-800 MHz |
varies |
128 GB |
AzuzA |
PCI-X |
HP-UX |
↑ up.
VME and scientific
Integrated PA-RISC systems on VME boards, VXI boards and scientific systems, based on HP 9000/715 and B-
Class workstations, used
for medical, industrial and military data measurement and real time control.
| Model |
CPU |
Cache |
RAM |
Design |
Expansion |
Operating systems |
|
| 742i/50 |
PA-7100 50 MHz |
128 KB |
64 MB |
ASP |
VME |
HP-UX Linux
NetBSD OpenBSD |
| 743i/64 |
PA-7100LC 64 MHz |
256 KB |
256 MB |
LASI |
GSC-M PMC VME |
HP-UX Linux
NetBSD OpenBSD |
V743/64 VXI E1497A |
PA-7100LC 64 MHz |
256 KB |
128 MB |
LASI |
GSC-M PMC VXI |
HP-UX probably others |
| 743i/100 |
PA-7100LC 100 MHz |
256 KB |
256 MB |
LASI |
GSC-M PMC VME |
HP-UX Linux
NetBSD OpenBSD |
V743/100 VXI E1498A |
PA-7100LC 100 MHz |
256 KB |
128 MB |
LASI |
GSC-M PMC VXI |
HP-UX probably others |
| 744/132L |
PA-7300LC 132 MHz |
128 KB |
1 GB |
LASI |
GSC-M PMC VME |
HP-UX Linux OpenBSD |
| 744/165L |
PA-7300LC 165 MHz |
128 KB L1 512 KB L2 |
1 GB |
LASI |
GSC-M PMC VME |
HP-UX Linux OpenBSD |
| 745i/50 |
PA-7100 50 MHz |
128 KB |
128 MB |
ASP |
EISA VME |
HP-UX Linux
NetBSD OpenBSD |
| 745i/100 |
PA-7100 100 MHz |
512 KB |
256 MB |
ASP |
EISA VME |
HP-UX Linux
NetBSD OpenBSD |
| 745/132L |
PA-7300LC 132 MHz |
128 KB |
1 GB |
LASI |
EISA PCI
GSC-M PMC VME |
HP-UX Linux OpenBSD |
| 745/165L |
PA-7300LC 165 MHz |
128 KB L1 512 KB L2 |
1 GB |
LASI |
EISA PCI
GSC-M PMC VME |
HP-UX Linux OpenBSD |
| 747i/50 |
PA-7100 50 MHz |
128 KB |
128 MB |
ASP |
EISA SGC VME |
HP-UX Linux
NetBSD OpenBSD |
| 747i/100 |
PA-7100 100 MHz |
512 KB |
256 MB |
ASP |
EISA SGC VME |
HP-UX Linux
NetBSD OpenBSD |
| 748i/64 |
PA-7100LC 64 MHz |
256 KB |
256 MB |
LASI |
EISA PCI
GSC-M PMC VME |
HP-UX Linux
NetBSD OpenBSD |
| 748i/100 |
PA-7100LC 100 MHz |
256 KB |
256 MB |
LASI |
EISA PCI
GSC-M PMC VME |
HP-UX Linux
NetBSD OpenBSD |
| 748i/132L |
PA-7300LC 132 MHz |
128 KB |
1 GB |
LASI |
EISA PCI
GSC-M PMC VME |
HP-UX Linux OpenBSD |
| 748i/165L |
PA-7300LC 165 MHz |
128 KB L1 512 KB L2 |
1 GB |
LASI |
EISA PCI
GSC-M PMC VME |
HP-UX Linux OpenBSD |
16600A Agilent |
PA-7300LC 150 MHz |
64 KB |
160 MB |
LASI |
Channel probes,
measurement,
emulation |
HP-UX LOGIC, probably others |
16700A Agilent |
PA-7300LC 150 MHz |
64 KB |
160 MB |
LASI |
Measurement,
emulation |
HP-UX LOGIC, probably others |
16700B Agilent |
PA-7300LC 150 MHz |
64 KB |
256 MB |
LASI |
Measurement,
emulation |
HP-UX LOGIC, probably others |
16702A Agilent |
PA-7300LC 150 MHz |
64 KB |
160 MB |
LASI |
Measurement,
emulation |
HP-UX LOGIC, probably others |
16702B Agilent |
PA-7300LC 150 MHz |
64 KB |
256 MB |
LASI |
Measurement,
emulation |
HP-UX LOGIC, probably others |
↑ up.
Mainframe
These are large enterprise servers for computing and large databases, with
a large range of expansion, CPUs, memory and storage.
Mostly multi-processor, some could be clustered also.
|